| Title | The Effect of Load Conditions for the Power of Mg-Air Fuel Cell | 
					
	| DOI | https://doi.org/10.5370/KIEEP.2012.61.3.134 | 
					
	| Keywords | Mg-Air fuel cell ; Mg electrode ; Air electrode ; Transient time ; Load current ; Load voltage ; Step current ; Ramp current ; Pulse current | 
					
	| Abstract | The power characteristics of the Mg-Air fuel cell were investigated with regard to variation of load conditions. The types of load current using for the Mg-Air fuel cell with 10% NaCl electrolyte were step type, ramp type and pulse type. It was found that transient phenomena occurred in the step current load, which is due to activate of the oxidation-reduction reaction process. And the transient time increase with the load current increase. In the load current of ramp type, the slop of voltage drop increased with current load slop {\alpha} increase. The load voltage and power decreased according to the pulse period of load current decrease were attributed to the metal sludges. |